audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

A/C Unit and Refrigerant Lines|Page 1135 > < A/C Unit and Refrigerant Lines|Page 1133
Page 3
background image

-

Remove the refrigerant line - A - from the A/C unit connecting flange.

‹› Seal open connections on the refrigerant lines/A/C unit with suitable sealing caps (to prevent dirt and moisture from entering).

Installing

Installation is done in reverse order, observe the following:

-

Replace the O-rings - C -. 

‹› Coat the O-ring with refrigerant oil before installing. Refer to => [ Refrigerant Circuit O-Rings ] See: Heating and Air Conditioning/Service and

Repair/Procedures/Refrigerant Circuit O-Rings.

‹› Make sure the O-ring seals - H - (different versions) are seated correctly in the groove - arrow - on the respective refrigerant line.

-

Check the connections - G - for the refrigerant line -  A - and the evaporator - B - for damage and ensure they are seated correctly.

-

Insert the O-ring seal in the groove - arrow - on the connection for the refrigerant line - A - and the evaporator -  B -.

-

Install the refrigerant lines - A and J - without tension.

-

Tighten the bolts - D and F -.

‹› Tightening specification: 9 Nm

-

Install new heat insulation - E - around both refrigerant line connections. 

-

Install the brackets - A and C - on the refrigerant lines.

A/C Unit and Refrigerant Lines|Page 1135 > < A/C Unit and Refrigerant Lines|Page 1133