audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

EVAP Canister Purge Regulator Valve 2, Checking|Page 3474 > < EVAP Canister Purge Regulator Valve 2, Checking|Page 3472
Page 3
background image

-

Operate the starter briefly.

Specified value: battery voltage.

If the specified value was not obtained:

-

Using a Multimeter, check the electrical harness connector terminal 1 to Ground (GND) for voltage.

-

Operate the starter briefly.

Specified value: battery voltage.

If the specified value was not obtained:

-

Check the wiring connection from the Evaporative Emission (EVAP) Canister Purge Regulator Valve 2 (N333) electrical harness connector
terminal 1 to the Motronic Engine Control Module (ECM) Power Supply Relay (J271) terminal 2/30 for an open circuit or short to ground (GND).

-

Check the electrical harness connector for damage, corrosion, lose or broken terminals.

-

If necessary, repair the wiring connection.

If the specified value was obtained:

Checking wiring

If the manufacturers test box is being used, perform the following step.

-

Install the test box. Refer to appropriate repair information.

If the manufacturers test box is not being used, perform the following step.

-

Remove the Engine Control Module (ECM) 2 (J624). Refer to appropriate repair information.

-

Using a Multimeter, check the Evaporative Emission (EVAP) Canister Purge Regulator Valve 2 (N333) electrical connector terminal 2 to the
Engine Control Module (ECM) 2 (J624) electrical connector T94a terminal 9 for an open circuit. 