audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Fuel Metering Valve 2, Checking|Page 3589 > < Fuel Metering Valve 2, Checking|Page 3587
Page 2
background image

-

Using a Multimeter , check the Fuel Metering Valve (N290) terminals 1 to 2 for resistance

Specified value: 450 to 1000 ohms.

If the specified value was not obtained:

-

Replace the High Pressure Fuel Pump. Refer to appropriate repair information.

If the specified value was obtained:

Checking voltage

Crank the engine.

-

Using a Multimeter, check the Fuel Metering Valve (N290) electrical harness connector terminal 1 to Ground (GND) for voltage.

Specified value: battery voltage.

-

Switch the ignition off.

If the specified value was not obtained:

-

Check the wiring from the Fuel Metering Valve (N290) electrical harness connector terminal 1 to the Motronic Engine Control Module (ECM)
Power Supply Relay (J271) socket 2/30 for a short circuit to Ground (GND), or an open circuit.

-

Check the electrical harness connector for damage, corrosion, lose or broken terminals.

-

If necessary, repair the wiring connection.

Fuel Metering Valve 2, Checking|Page 3589 > < Fuel Metering Valve 2, Checking|Page 3587