Oxygen Sensor: Testing and Inspection
Oxygen Sensor (O2S) 1 Heater Behind Catalytic Converter TWC, Checking

Oxygen Sensor (O2S) 1 Heater Behind Catalytic Converter TWC, Checking

The following procedure is used to diagnose Oxygen Sensor (O2S) 1 (behind Three Way Catalytic Converter (TWC)) Heater (Z29) for Oxygen
Sensor (O2S) Behind Three Way Catalytic Converter (TWC) (G130) which is controlled by the Motronic Engine Control Module (ECM) (J623).

‹› When servicing terminals in harness connector of Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) use only gold-plated

terminals.

Special tools, testers and auxiliary items required

‹› Multimeter.

‹› Wiring diagram.

Test requirements

‹› Fuse (SC5) OK.

‹› Battery voltage at least 12.5 volts.

‹› All electrical consumers such as, lights and rear window defroster, switched off.

‹› Vehicles with automatic transmission, shift selector lever into position " P" or "N".

‹› A/C switched off.

‹› Ground (GND) connections between engine/transmission/chassis OK.

‹› Ignition switched off.

Test Procedure

-

Perform a preliminary check to verify the customers complaint. Refer to => [ Preliminary Check ] See: Computers and Control Systems/Testing
and Inspection/Scan Tool Testing and Procedures/Preliminary Check

-

Raise the vehicle.

-

Loosen the quick release fasteners - 1 - and -  2 - and remove the noise insulation panel.