audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Heated Oxygen Sensor 2 Before Catalytic Converter, Checking|Page 2548 > < Heated Oxygen Sensor 2 Before Catalytic Converter, Checking|Page 2546
Page 3
background image

Specified value: 1.0 to 20.0 ohms (at approx. 20° C)

If the specification was not obtained:

-

Replace the Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) (G130). Refer to appropriate repair information.

If the specification was obtained:

Checking voltage supply

Crank the engine.

-

Using a multimeter, check the Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) (G130) electrical harness connector terminal
1 to Ground (GND) for voltage. 

Specified value: Battery voltage.

Switch the ignition off.

If the specification was not obtained:

-

Check the wiring from the Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) (G130) electrical harness connector terminal 1 to
the Motronic Engine Control Module (ECM) Power Supply Relay (J271) socket 2/30 or a short circuit to each other, Ground (GND) or an open
circuit.

Heated Oxygen Sensor 2 Before Catalytic Converter, Checking|Page 2548 > < Heated Oxygen Sensor 2 Before Catalytic Converter, Checking|Page 2546