Oxygen Sensor: Testing and Inspection
Heated Oxygen Sensor Before Catalytic Converter, Checking

Heated Oxygen Sensor Before Catalytic Converter, Checking

The following procedure is used to diagnose Heated Oxygen Sensor (HO2S) (G39) which is controlled by the Motronic Engine Control Module
(ECM) (J623).

‹› Use only gold-plated terminals when servicing terminals in the electrical harness connectors of the Heated Oxygen Sensor (HO2S) (G39).

Special tools, testers and auxiliary items required

‹› Multimeter.

‹› Wiring diagram.

Test requirements

‹›  The Motronic Engine Control Module (ECM) (J623) fuses OK.

‹› The Oxygen Sensor (O2S) Heater (Z19) before catalytic converter OK.

‹› Battery voltage at least 12.5 volts.

‹› All electrical consumers such as, lights and rear window defroster, switched off.

‹› A/C switched off.

‹› Ground (GND) connections between engine/transmission/chassis OK.

‹› Exhaust system between catalytic converter and cylinder head properly sealed.

‹› Coolant Temperature at least 80° C.

Function test

-

Perform the function test located in diagnostic mode 06. Refer to => [ OBDMID 01 ($01): Oxygen Sensor

Monitor Bank 1 - Sensor 1 ] See: Computers and Control Systems/Testing and Inspection/Scan Tool Testing and Procedures/Diagnostic Modes 01 - 0A.

If specified values are obtained:

-

End diagnosis and switch the ignition off.

If the specified values are not obtained:

Test Procedure

-

Perform a preliminary check to verify the customers complaint. Refer to => [ Preliminary Check ] See: Computers and Control Systems/Testing
and Inspection/Scan Tool Testing and Procedures/Preliminary Check

-

Raise the vehicle.

-

Loosen the quick release fasteners - 1 - and -  2 - and remove the noise insulation panel.