audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Central Venting System|Page 5366 > < Central Venting System|Page 5364
Page 1
background image

Battery: Description and Operation
Acid Density, Measuring

Non Maintenance Free Battery, without a Visual Indicator

Lead acid batteries that are non maintenance free are filled with electrolyte fluid (wet battery). They have sealing plugs.

CAUTION!
Risk of injury from direct exposure to battery acid!

‹› Observe the warning notes and safety precautions. Refer to => [ There is a risk of injury from the

battery acid. ] See: Service Precautions/Technician Safety Information/Lead Acid Battery Warnings and Safety Precautions.

Risk of explosion due to the explosive gas that forms during battery charging.

‹› Observe the warning notes and safety precautions. Refer to => [ Risk of explosion due to the explosive

gas that forms during battery charging. ] See: Service Precautions/Technician Safety Information/Lead Acid Battery Warnings and Safety
Precautions.

Acid Density, Measuring

Special tools, testers and auxiliary items required

‹› Refractometer (T10007) or

‹› Commercially available Hydrometer

Procedure

In conjunction with the battery testing using the battery tester (VAS 6161), refer to => [ Battery Testing, using VAS 6161 ] See: Testing and
Inspection/Battery Checking, Vehicles Without a Battery Monitoring Control Module or Energy Management Control Module or the battery tester
with printer (VAS 5097A), refer to => [ Battery Testing, using VAS 5097A ] See: Testing and Inspection/Battery Checking, Vehicles Without a
Battery Monitoring Control Module or Energy Management Control Module, the acid density test provides information about the condition of the
battery.

‹› The temperature of the battery acid must be at least 10 °C (50 °F).

CAUTION!
Risk of injury from direct exposure to battery acid.

‹› Follow accident prevention regulations when working with battery acid. Refer to => [ There is a risk of injury from the

battery acid. ] See: Service Precautions/Technician Safety Information/Lead Acid Battery Warnings and Safety Precautions.

‹› Wear protective eyewear and clothing. Refer to => [ Protect against injury by using

protective eyewear and clothing. ] See: Service Precautions/Technician Safety Information/Lead Acid Battery Warnings and Safety
Precautions.

‹› Specific density of the electrolyte can be checked immediately after charging battery.

-

Remove all sealing plugs from the battery cells.

-

Insert the hydrometer into the battery cell and siphon off enough electrolyte until the float floats freely in electrolyte.

Central Venting System|Page 5366 > < Central Venting System|Page 5364