Page 1
background image

Battery: Testing and Inspection
Battery Checking, Vehicles Without a Battery Monitoring Control Module or Energy Management
Control Module

Battery Checking, Vehicles without a Battery Monitoring Control Module or Energy Management Control Module

=> [ Battery Testing, using VAS 6161 ] 

=> [ Battery Testing, using VAS 5097A ] 

=> [ Measuring the No Load Voltage ] 

=> [ Battery Test via Current Draw ] 

Maintenance free batteries must not be opened. Otherwise, the warranty is voided.

Battery Testing, using VAS 6161

‹› When performing the battery test with the battery tester (VAS 6161), the battery ground cable must not be disconnected.

‹› When using the (VAS 6161) the battery is no longer being charged. The principle of dynamic conductivity measurement is applied. As a result,

numerous measurements are possible without recharging the battery.

‹› The no load voltage measurement can be performed without a waiting period.

‹› All battery types are stored in the device. They can be refreshed by performing an update.

‹› The battery barcode can be directly recorded via the optional 2D scanner.

‹› The integrated temperature sensor increases the quality of the measurements.

‹› The data can be stored on a SD memory card. 

‹› For information about the (VAS 6161), refer to the operating instructions.

Special tools, testers and auxiliary items required

‹› Battery Tester (VAS 6161)

‹› Using the (VAS 6161), refer to the operating instructions.

Procedure

‹› The battery temperature must be at least 10 °C (50 °F).

CAUTION!
There is a risk of injury from the battery acid.

‹› Follow accident prevention regulations when working with battery acid. Refer to => [ There is a risk of injury from the

battery acid. ] See: Service Precautions/Technician Safety Information/Lead Acid Battery Warnings and Safety Precautions.

‹› Wear protective eyewear and clothing. Refer to => [ Protect against injury by using

protective eyewear and clothing. ] See: Service Precautions/Technician Safety Information/Lead Acid Battery Warnings and Safety
Precautions.

‹› On non maintenance free batteries, the sealing plugs must always be firmly tightened during the voltage under load measurement.

Risk of explosion on discharged battery with "visual indicator".

‹› If the "visual indicator" has no color or is light yellow, the battery may not be tested or charged. Jump starting must not be used!

There is a risk of explosion during testing, charging or jump starting. The battery must be replaced.

-

Turn off the ignition and all electrical consumers.

Battery No Load Voltage, Checking|Page 5393 > < Battery No Load Voltage, Checking|Page 5391