‹› Specified value: The charge current must be higher than 10% of the nominal capacity.

‹› Example: Charge current on a 60 Ah battery after 5 minutes of charging: greater than 6 A.

-

If the target value is reached, proceed with the charging operation until the battery is fully charged.

-

Then test the battery with the battery tester:

‹› With the (VAS 6161) without a waiting period. Refer to => [ Battery Testing, using VAS 6161 ].

‹› With the (VAS 5097A) after a 12 hour waiting period following charging. Refer to => [ Battery Testing, using VAS 5097A ].

-

If the specified value is not met, replace the battery. 

‹› If the battery must be replaced, follow the disposal regulations. Refer to => [ Pollution risk. ] See: Service Precautions/Technician Safety

Information/Lead Acid Battery Warnings and Safety Precautions.