R8 Quattro Coupe V10-5.2L (BUJ) (2010)
‹› Specified value: The charge current must be higher than 10% of the nominal capacity.
‹› Example: Charge current on a 60 Ah battery after 5 minutes of charging: greater than 6 A.
-
If the target value is reached, proceed with the charging operation until the battery is fully charged.
-
Then test the battery with the battery tester:
‹› With the (VAS 6161) without a waiting period. Refer to => [ Battery Testing, using VAS 6161 ].
‹› With the (VAS 5097A) after a 12 hour waiting period following charging. Refer to => [ Battery Testing, using VAS 5097A ].
-
If the specified value is not met, replace the battery.
‹› If the battery must be replaced, follow the disposal regulations. Refer to => [ Pollution risk. ] See: Service Precautions/Technician Safety
Information/Lead Acid Battery Warnings and Safety Precautions.