Exhaust Pressure Regulator Vacuum Reservoir: Testing and Inspection

Exhaust Flap Vacuum Reservoir, Checking

Special tools, testers and auxiliary items required

-

Hand vacuum pump VAS 6213 or hand vacuum pump V.A.G 1390

Work procedure

-

Disconnect hose on vacuum diaphragm for exhaust flap at rear muffler.

-

Connect Hand Vacuum Pump V.A.G 1390 or VAS 6213 to vacuum  diaphragm.

-

Generate vacuum using hand vacuum pump.
-

Linkage must move toward front.

-

Vent hand vacuum pump.
-

Linkage must move toward rear.

If linkage does not move:

-

Check linkage for ease of movement and check vacuum diaphragm for leaks.