audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Engine Control Module|Page 3477 > < Engine Control Module|Page 3475
Page 3
background image

CAUTION!
The shear bolts that are screwed into the Engine Control Module (ECM) (J623), are not coated with a locking compound and do not
require heating. Do not heat the Engine Control Module (ECM) (J623) or damage to the Engine Control Module (ECM) (J623) may
occur.

To avoid damage (burning) of wire connections and harness connectors, insulation and control modules, the following work steps must be
adhered to exactly! Observe operating instructions for heat gun.

-

Using a Heat gun set at its lowest setting, heat the shear bolt for approx. 20 to 25 seconds.

-

Remove the shear bolt with locking pliers. Discard the used shear bolts.

Repeat the previous steps for the second shear bolt.

-

Remove the protective housing from the Motronic Engine Control Module (ECM) (J623).

‹› Adaptation values are erased when the connectors are disconnected from the Motronic Engine Control Module (ECM) (J623), DTC memory

content remains intact.

-

Disconnect the electrical harness connectors from the Motronic Engine Control Module (ECM) (J623).

Installing

Installation is in the reverse order of removal. Note the following: 

-

The ECM must be installed with the protective housing.

-

Use new shear bolts.

Engine Control Module|Page 3477 > < Engine Control Module|Page 3475