audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Fuel Metering Valve 1, Checking|Page 4070 > < Fuel Metering Valve 1, Checking|Page 4068
Page 2
background image

If the specified value was obtained:

Checking voltage

-

Switch the ignition on.

-

Using a Multimeter , check the Fuel Metering Valve 2 N402 electrical harness connector terminal 1 to Ground (GND) for voltage.

-

Switch the ignition off.

Specified value: battery voltage.

If the specified value was not obtained:

-

Check the wiring from the Fuel Metering Valve 2 N402 electrical harness connector terminal 1 to the Engine Component Power Supply Relay
J757 terminal 2/87 for a short circuit to Ground (GND), or an open circuit.

-

Check the electrical harness connector for damage, corrosion, lose or broken terminals.

-

If necessary, repair the wiring connection.

If no malfunctions are found in the wiring:

Checking wiring connections

If the manufacturers test box is being used. Perform the following step.

-

Install the test box.

If the manufacturers test box is not being used. Perform the following step.

-

Remove the Engine Control Module (ECM) 2 J624.

-

Using a multimeter , check the Fuel Metering Valve 2 N402 electrical harness connector terminal 2 to the Engine Control Module (ECM) 2 J624
electrical harness connector T60a terminal 35 for an open circuit.

Fuel Metering Valve 2 N402

Engine Control Module (ECM) 2

electrical harness connector

J624 electrical connector T60a

terminal

terminal or test box socket

2

19

Specified value: 1.5 Ohms Max.

If the specification was not obtained:

-

Check the wiring for a short circuit to each other, Battery (+), and Ground (GND), or an open circuit.

Fuel Metering Valve 1, Checking|Page 4070 > < Fuel Metering Valve 1, Checking|Page 4068