audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Fuel Metering Valve 1, Checking|Page 4102 > < Fuel Metering Valve 1, Checking
Page 2
background image

Specified value: 450 to 1000 ohms.

If the specified value was not obtained:

-

Replace the High Pressure Fuel Pump. Refer to Fuel Injection and Ignition Repair Information

If the specified value was obtained:

Checking voltage

Crank the engine.

-

Using a Multimeter, check the Fuel Metering Valve (N290) electrical harness connector terminal 1 to Ground (GND) for voltage.

Specified value: battery voltage.

-

Switch the ignition off.

If the specified value was not obtained:

-

Check the wiring from the Fuel Metering Valve ( N290) electrical harness connector terminal 1 to the Engine Component Power Supply Relay
(J757) socket 2/87 for a short circuit to Ground (GND), or an open circuit.

-

Check the electrical harness connector for damage, corrosion, lose or broken terminals.

-

If necessary, repair the wiring connection.

If no malfunctions are found in the wiring:

Fuel Metering Valve 1, Checking|Page 4102 > < Fuel Metering Valve 1, Checking