Hose/Line HVAC: Procedures

Connections Of Refrigerant Lines To The Components (different Versions)

NOTE:

-

In January 2003, the connections between the refrigerant lines and the various components (condenser, evaporator etc.) were converted from
radial/axial sealing to radial sealing (gradual introduction). A further few thousand vehicles were still installed with the old type of connection in
April / May 2003.

-

It is only permissible to combine components with the same type of seal and the corresponding O-rings (different versions).

-

Reliable sealing of the joints cannot be ensured if components with different forms of sealing are installed. 

-

Joints with radial/axial seal (installed up to January 2003, gradually discontinued)

-

Component - A - (e.g. condenser) with connection for radial/axial seal

-

O-ring - B - for connection with radial/axial seal

-

Refrigerant line - C - with connection with radial/axial seal

-

Joints with radial seal (as of January 2003, gradual introduction)

-

Component - A - (e.g. condenser) with connection for radial seal

-

O-ring - B - for connection with radial seal

-

Refrigerant line - C - with connection with radial seal

-

Guide sleeve - D - (plastic) at connection with radial seal