Fuel Distributor: Testing and Inspection

Fuel Metering Valve N290, Checking

Special tools, testers and auxiliary items required

-

Multimeter.

-

Wiring diagram.

Test requirements

-

The Fuel Pump (FP) Control Module J538 OK.

-

The Engine Component Power Supply Relay J757 OK.

-

The Fuse S282 OK.

-

The fuel filter OK.

-

The parking brake engaged.

-

The battery voltage at least 12.5 V.

-

The selector lever of automatic transmission in position "P" or "N".

-

All electrical consumers switched off (radiator fan must NOT run during test).

-

A/C switched off.

-

The fuel tank at least 1 / 4 filled.

-

The ignition switched off.

Procedure

-

Disconnect the Fuel Metering Valve N290 electrical harness connector - arrow -.

Checking internal resistance

-

Using a Multimeter, check the Fuel Metering Valve N290 terminals 1 to 2 for resistance
Specified value: 450 to 1000 Ohms.

If the specified value was not obtained:

-

Replace the High Pressure Fuel Pump.

If the specified value was obtained:

Checking voltage

Crank the engine.