RS 4 Quattro Sedan V8-4.2L (BNS) (2007)
Fuel Distributor: Testing and Inspection
Fuel Metering Valve N290, Checking
Special tools, testers and auxiliary items required
-
Multimeter.
-
Wiring diagram.
Test requirements
-
The Fuel Pump (FP) Control Module J538 OK.
-
The Engine Component Power Supply Relay J757 OK.
-
The Fuse S282 OK.
-
The fuel filter OK.
-
The parking brake engaged.
-
The battery voltage at least 12.5 V.
-
The selector lever of automatic transmission in position "P" or "N".
-
All electrical consumers switched off (radiator fan must NOT run during test).
-
A/C switched off.
-
The fuel tank at least 1 / 4 filled.
-
The ignition switched off.
Procedure
-
Disconnect the Fuel Metering Valve N290 electrical harness connector - arrow -.
Checking internal resistance
-
Using a Multimeter, check the Fuel Metering Valve N290 terminals 1 to 2 for resistance
Specified value: 450 to 1000 Ohms.
If the specified value was not obtained:
-
Replace the High Pressure Fuel Pump.
If the specified value was obtained:
Checking voltage
Crank the engine.