audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Fuel Metering Valve 1, Checking|Page 4521 > < Fuel Metering Valve 1, Checking|Page 4519
Page 1
background image

Fuel Pressure Regulator: Testing and Inspection
Fuel Metering Valve 2, Checking

Fuel Metering Valve 2, Checking

Special tools, testers and auxiliary items required

‹› Multimeter.

‹› Wiring diagram.

Test requirements

‹› The Fuel Pump (FP) Control Module (J538) OK. 

‹› The Engine Component Power Supply Relay (J757) OK.

‹› The Fuse (S282) OK.

‹› The fuel filter OK.

‹› The parking brake engaged.

‹› The battery voltage at least 12.5 V.

‹› The selector lever of automatic transmission in position "P" or " N".

‹› All electrical consumers switched off (radiator fan must NOT run during test).

‹› A/C switched off.

‹› The fuel tank at least 1/4 filled.

‹› The ignition switched off.

Test procedure

-

Perform a preliminary check to verify the customers complaint. Refer to => [ General Diagnosis ] See: Computers and Control Systems/Testing
and Inspection/Initial Inspection and Diagnostic Overview/General Diagnosis.

Start diagnosis

-

Disconnect the Fuel Metering Valve 2 (N402) electrical harness connector - arrow -.

Checking internal resistance 

-

Using a Multimeter , check the Fuel Metering Valve 2 (N402) terminals for resistance

Fuel Metering Valve 1, Checking|Page 4521 > < Fuel Metering Valve 1, Checking|Page 4519