audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Knock Sensors 1 and 2, Checking|Page 4771 > < Knock Sensors 1 and 2, Checking|Page 4769
Page 3
background image

Specified value: 1.5 ohms Max.

If the specified value was not obtained:

-

Check the wiring connection for an open circuit, short circuit to Battery (+) or Ground (GND).

-

Check the wiring connection for damage, corrosion, lose or broken terminals.

-

If necessary, repair the faulty wiring connection.

If no malfunction is found in the wiring and the resistance was not OK:

-

Replace the faulty Knock Sensor 3 (G198) or Knock Sensor 4 (G199). Refer to Fuel Injection and Ignition Repair Information.

If no malfunction is found in the wiring and the resistance was OK: 

-

Replace the Engine Control Module (ECM) 2 (J624 ).

-

Install the Intake manifold. Refer to Fuel Injection and Ignition Repair Information.

Final procedures

After repair work, the following work steps must be performed in the following sequence:

1. Check the DTC memory. Refer to => [ Diagnostic Mode 03 - Read DTC Memory ] See: Computers and Control Systems/Testing and

Inspection/Scan Tool Testing and Procedures/Diagnostic Mode 03 - Read DTC Memory.

2. If necessary, erase the DTC memory. Refer to => [ Diagnostic Mode 04 - Erase DTC Memory ] See: Computers and Control Systems/Testing and

Inspection/Scan Tool Testing and Procedures/Diagnostic Mode 04 - Erase DTC Memory. 

3. If the DTC memory was erased, generate readiness code. Refer to => [ Readiness Code ] See: Computers and Control Systems/Testing and

Inspection/Monitors, Trips, Drive Cycles and Readiness Codes.

-

End of diagnosis.

Knock Sensors 1 and 2, Checking|Page 4771 > < Knock Sensors 1 and 2, Checking|Page 4769