audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Fuel Level Sensor|Service and Repair > < Fuel Level Sensor|Locations|Page 1171
Page 2
background image

-

Disconnect electrical harness connector - arrow - at left locking flange.

-

Connect hand multimeter V.A.G 1526 C between terminal - 2 - and - 3 - for resistance measurement.

NOTE:
-

If measured value is 0 Ohm there is a short circuit. If measured value is infinity Ohm there is and open circuit in the wiring.

-

To check resistance values "tank full" or "tank empty" , the Fuel Level Sensor 2 G169 must be removed and the sensor floater must be placed
in upper or lower end position.

-

With Fuel Level Sensor 2 G169 removed, the following values are obtained because of the greater deflection of the floater arm

Fuel Level Sensor|Service and Repair > < Fuel Level Sensor|Locations|Page 1171