‹› CAN bus wires have the following color coding:

‹› During repair work, both bus wires must have the same length. When twisting the wires - 1 and 2 - together, the - A - = 20 mm routing length must

be maintained.

‹› While doing so, no section of wire must be greater than -  - = 50 mm without twisting of wires, e.g. in area of welded connectors -  arrow -.