After-Run Coolant Pump: Testing and Inspection
Coolant Circulation Pump Relay -J151-, Checking

Coolant Circulation Pump Relay -J151-, checking

Note: Refer to Function, Special tools and equipment

^

V.A.G 1526 A

^

V.A.G 1594 A

Requirements for test: 
^

After-Run Coolant Pump -V51 - tested, test result- "Supply voltage not OK.11

^

Coolant temperature at least 60°C when engine is turned off; this ensures that After Run Coolant Pump starts up,

Test sequence 
-

Switch ignition off.

Note:  Test must be performed within 15 minutes after switching off ignition.

-

Remove rubber seal from plenum chamber in direction of (arrow).

-

Remove plenum chamber cover -1- from front.