Unplug electrical connector at Oil Level Thermal Sensor -G266- -item 1-.

-

Unbolt lower section of sump (arrow).

-

Unbolt baffle plate (arrows).

-

Remove locking ring.

-

Pull intake connection (arrow) off oil pump.