audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Housing Assembly HVAC|Service and Repair|Page 10091 > < Refrigerant Lines From Denso Compressor|Page 10087
Page 1
background image

Housing Assembly HVAC: Service and Repair

Air Distribution Housing, Disassembling And Assembling

-

Disassembling and assembling air conditioner unit.

NOTE:

-

Starting September 1998, there was a running change in production from the version "1" air conditioner to the version "2" air conditioner.

-

From model year 2002 air conditioner version "3" is installed

-

From model year 2002 for vehicles with compressor using A/C Compressor Regulator Valve -N280-, an additional Evaporator Vent Temperature
Sensor is installed.(On vehicles without -G263- the opening is closed with a plug).

1

-

Bolt

2

-

Clip

3

-

Foam sealing pad
-

For condenser drainage duct

4

-

Bottom section of air distributor housing
-

With condensation drainage duct

-

Lower part of version "2" was adapted to modified evaporator

5

-

Drip pan
-

For condensation from evaporator

6

-

Evaporator
-

With seal

-

From version "2", the width of the evaporator is 32 mm less than the width of the evaporator in version "1".

Housing Assembly HVAC|Service and Repair|Page 10091 > < Refrigerant Lines From Denso Compressor|Page 10087