audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Table For Channels and Adaption Values|Page 13594 > < Table For Channels and Adaption Values|Page 13592
Page 1
background image

Maintenance Required Lamp/Indicator: Service and Repair
Channel 41 (Time Since Service)

Adaptation (function 10)

individual functions are called up by entering the appropriate adaptation channel numbers (see adaptation table).  See: Table For Channels and Adaption
Values

Initiating "Adaptation" function 10

-

Initiate output Diagnostic Test Mode of instrument cluster.  See: Adaptation Function Initiation

Adaptation Channel 41 - Time Since Service

This function is used to input the time in days since the last service.

Display on VAS5051
-

Select function "4" in button field -2- For Adaptation channel 41" and press Q button to confirm input.

Display on VAS5051
1

-

Channel 41 read and test

2

-

Actual value in spec. in 1 day increments.

3

-

Keypad - only direct input via the keypad is possible

4

-

The sliding bar is positioned on the current adaptation value, e.g. 110
Time in days since last service is displayed (here For example 110 represents 110 days)

Note:
-

Input of the current specified value is only possible in units of one day, indication in display also changes by units of one day.

Table For Channels and Adaption Values|Page 13594 > < Table For Channels and Adaption Values|Page 13592