Channel 41 (Time Since Service)
Adaptation (function 10)
individual functions are called up by entering the appropriate adaptation channel numbers (see adaptation table). See: Table For Channels and Adaption
Values
Initiating "Adaptation" function 10
-
Initiate output Diagnostic Test Mode of instrument cluster. See: Adaptation Function Initiation
Adaptation Channel 41 - Time Since Service
This function is used to input the time in days since the last service.
Display on VAS5051
-
Select function "4" in button field -2- For Adaptation channel 41" and press Q button to confirm input.
Display on VAS5051
1
-
Channel 41 read and test
2
-
Actual value in spec. in 1 day increments.
3
-
Keypad - only direct input via the keypad is possible
4
-
The sliding bar is positioned on the current adaptation value, e.g. 110
Time in days since last service is displayed (here For example 110 represents 110 days)
Note:
-
Input of the current specified value is only possible in units of one day, indication in display also changes by units of one day.