audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Table For Channels and Adaption Values|Page 13598 > < Table For Channels and Adaption Values|Page 13596
Page 1
background image

Maintenance Required Lamp/Indicator: Service and Repair
Channel 43 (Max. Mileage)

Adaptation (function 10)

individual functions are called up by entering the appropriate adaptation channel numbers (see adaptation table).  See: Table For Channels and Adaption
Values

Initiating "Adaptation" function 10

-

Initiate output Diagnostic Test Mode of instrument cluster.  See: Adaptation Function Initiation

Adaptation Channel 43 - Maximum Mileage Performance

This function is used to specify a fixed maximum mileage performance in the instrument cluster For the SRI. 

Display on VAS5051:
-

Select function "43" in button field -2- for "Adaptation channel 43" and press Q button to confirm input.

Display on VAS5051:
1

-

Channel 43 read and test

2

-

Maximum value Oil in 1000 mile increments.

3

-

Keypad - only direct input via the keypad is possible

4

-

The sliding bar is positioned on the current adaptation value, e.g. 8 The maximum mileage performance up to a service will be displayed (here
For example 10 represents 10000 miles).

Note:

-

Input of current specified value is only possible in units of 1000 miles, therefore indication in display also changes in 1000 mile  units.

-

Change adaptation value via direct input using keypad, not with the sliding bar.

-

Enter 5-digit adaptation value. Insert zeros in front.

Example:

Table For Channels and Adaption Values|Page 13598 > < Table For Channels and Adaption Values|Page 13596