RS 6 V8-4.2L Turbo (BCY) (2003)
and Control Systems/Testing and Inspection/Scan Tool Testing and Procedures/Scan Tool Connecting and Initial Checks/Connecting VAS 5051
Scan Tool
-
Check for open circuit and short to Ground/positive in following wiring.
Connector
Test box V.A.G 1598/31
Contact
Socket
1
72
2
73
3
36
4
35
5
33
6
34
-
Eliminate open circuit in wiring/short circuit if necessary.
If no fault is found in wiring:
-
Replace accelerator pedal position senders.