audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Left Front Exhaust Pipe With Primary and Main Catalytic Converter, Removing and Installing|Page 3784 > < Left Front Exhaust Pipe With Primary and Main Catalytic Converter, Removing and Installing
Page 2
background image

-

Remove cover -1- on left of engine compartment.

-

Pinch off coolant hose -1- with hose clamp 3094 and disconnect at coolant expansion tank.

-

Remove bolts (arrows) and coolant expansion tank -2-.

-

Disconnect wire to Engine Coolant Level (ECL) warning switch -F66- at bottom of expansion tank and lay aside coolant expansion tank with
coolant hose -3- connected.

-

If necessary, use suitable plug to seal connection.

-

Take connectors -1  4- out of holder on left of bulkhead.

-

Disconnect connectors -1- and -4-.

-

Remove holder at bulkhead.

-

Remove heat insulation sleeve at wiring harness and wiring harness clear.

-

Move oxygen sensor wiring downward and clear.

-

Remove front left wheel.

-

On vehicles with auxiliary heater, remove bolts (arrows) for exhaust pipe of auxiliary/additional heater at sound insulation.

Left Front Exhaust Pipe With Primary and Main Catalytic Converter, Removing and Installing|Page 3784 > < Left Front Exhaust Pipe With Primary and Main Catalytic Converter, Removing and Installing