Air Door Actuator / Motor: Service and Repair
Air Flow Flap Motor V71, Removing and Installing

Air Flow Flap Motor V71, Removing And Installing

NOTE:  The flaps moved by this control motor are the fresh-air and air flow flaps.

Removing

-

Remove glove compartment.

-

Disconnect connector - A -.

-

Remove bolts - B -.

-

Remove Air Flow Flap Motor V71.

Installing

NOTE:  The control motor cam plate is color-coded; for the Air Flow Flap Motor V71 it is light blue.

-

Insert lug - A - in groove - C - and lug - B - in groove - D - of cam plate (lugs - A - and - B - as well as grooves - C - and - D - have different
dimensions).

NOTE:  When inserting, make sure that actuating arms - E- and - F - are correctly positioned on the corresponding pivot pins.

Reinstall all parts removed in reverse order, paying attention to the following:

-

Lay wiring harness such that it cannot come into contact with moving components (e.g. control motor lever).

-

Check and erase DTC memory; perform basic setting.

NOTE:  Operation of the control motor can be checked as follows: Connect the two contacts "5" and "6" in the control motor connector to a 12 V DC
source. The control motor moves as far as the stop in one direction. Interchanging positive and negative reverses direction. Use adapter for this purpose.