A/C Coupler O-ring: Service and Repair

O-ring Seals For Refrigerant Circuit

-

Always replace, only to be used once.

-

Moisten slightly with refrigerant oil before installing.

-

Ensure correct positioning on line/in groove.

-

Ensure cleanliness when working.

NOTE:

-

Only O-rings which are resistant to refrigerant R134a and the corresponding refrigerant oil may be installed. Such O-rings are color coded to
prevent mix-ups (currently "red", "light purple" or "dark purple").

-

In addition to the colored O-rings, black O-rings are also used at the factory for certain connections.

-

Dimensions -a- and -b- differ depending on installation of O-ring.

-

In January 2003, the connections between the refrigerant lines and the various components (condenser, evaporator etc.) were converted from
radial/axial sealing to radial sealing. It is only permissible to combine components with the same type of seal and the corresponding O-rings
(different versions). Reliable sealing of the joints cannot be ensured if components with different forms of sealing are installed.