S4 V8-4.2L (BHF) (2004)
NOTE: Replace seal.
-
Place fuel level sensor G into guide in outer part of baffle housing and press it downward - arrow - until it is audibly engaged.
-
Connect electrical connection - arrow - on inner side of locking flange.
-
Install new locking flange seal dry.
-
Bring locking flange to installation position.
-
Tab - 2 - on locking flange must lie between tabs - 1 - and - 3 - on fuel tank.
NOTE: Arrow - points in direction of travel.
-
Tighten locking ring.
-
Connect battery. Observe safety precautions after connecting battery
Torque specifications
Component
Nm
Locking ring for fuel delivery unit
145