Valve must click

-

Valve must open and close (can be tested by blowing into assisting hose)

-

End function "03 - output Diagnostic Test Mode (DTM)" by pressing button.

-

Select "06 - End Output".

-

Switch ignition off.

If valve does not open or close properly:

-

Replace Secondary Air Injection (AIR) Solenoid Valve -N112-.

If valve does not click during output Diagnostic Test Mode (DTM):

-

Check internal resistance.

Checking internal resistance

-

Disconnect electrical harness connector from Secondary Air Injection (AIR) Solenoid Valve -N112- - arrow -.

-

Connect multimeter to valve for resistance measurement.
-

Specified value: 19 to 27

If specified value is not obtained:

-

Replace Secondary Air Injection (AIR) Solenoid Valve -N112-.

If specified value is obtained:

-

Check voltage supply.

Checking voltage supply

-

Fuse for Secondary Air Injection (AIR) solenoid valve OK Electrical Wiring Diagrams, Troubleshooting Component Locations

-

Fuel Pump (FP) Relay -J17- OK

NOTE:  Voltage is supplied to the Secondary Air Injection (AIR) Solenoid Valve -N112- via the Fuel Pump (FP) Relay -J17-.