audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Combination Valve For Secondary Air Injection (AIR), Checking Function and For Proper Seal|Page 5088 > < Combination Valve For Secondary Air Injection (AIR), Checking Function and For Proper Seal|Page 5086
Page 5
background image

-

LED must blink

-

End function "03 - output Diagnostic Test Mode (DTM)" by pressing button.

-

Select "06 - End Output".

-

Switch ignition off.

If LED does not blink or if it remains constantly lit:

-

Connect test box V.A.G 1598/31 to wiring harness connectors, Engine Control Module (ECM) is not connected. Connect Ground (GND) clip at
test box to Ground (not visible in illustration).

CAUTION:  To avoid damaging electronic components, set measuring range before connecting test leads and observe all test requirements.

-

Check following wiring connection for open circuit and short circuit to Ground (GND) and B+:

Harness connector

Test box V.A.G 1598/31Socket

Terminal

-2-

 44

-

Repair wiring connection if necessary.

-

Install lock carrier with attachments.

-

Place torque support on rubber buffer for torque support and tighten bolts - arrows -.

-

Install front bumper cover

-

Check headlight adjustment ; Headlights, checking adjustment.

Combination Valve For Secondary Air Injection (AIR), Checking Function and For Proper Seal|Page 5088 > < Combination Valve For Secondary Air Injection (AIR), Checking Function and For Proper Seal|Page 5086