LED must blink
-
End function "03 - output Diagnostic Test Mode (DTM)" by pressing button.
-
Select "06 - End Output".
-
Switch ignition off.
If LED does not blink or if it remains constantly lit:
-
Connect test box V.A.G 1598/31 to wiring harness connectors, Engine Control Module (ECM) is not connected. Connect Ground (GND) clip at
test box to Ground (not visible in illustration).
CAUTION: To avoid damaging electronic components, set measuring range before connecting test leads and observe all test requirements.
-
Check following wiring connection for open circuit and short circuit to Ground (GND) and B+:
Harness connector
Test box V.A.G 1598/31Socket
Terminal
-2-
44
-
Repair wiring connection if necessary.
-
Install lock carrier with attachments.
-
Place torque support on rubber buffer for torque support and tighten bolts - arrows -.
-
Install front bumper cover
-
Check headlight adjustment ; Headlights, checking adjustment.