Secondary Air Injection (AIR) Pump Relay -J299- - item 2 - (in electronics box, in plenum chamber) must engage and Secondary Air Injection
(AIR) Pump Motor -V101- must run in intervals.

-

End function "03 - output Diagnostic Test Mode (DTM)" by pressing button.

-

Select "06 - End Output".

-

Switch ignition off.
A. If relay does not trigger:

-

Check voltage supply of Secondary Air Injection (AIR) Pump Relay -J299-

-

Check activation of Secondary Air Injection (AIR) Pump Relay -J299-
B. If relay triggers, but Secondary Air Injection (AIR) Pump Motor -V101- does not run:

-

Check voltage supply for Secondary Air Injection (AIR) Pump Motor -V101-.

-

Checking voltage supply for Secondary Air Injection (AIR) Pump Relay -J299-

-

Fuse in fuse holder -S234- (position - 34 - ) OK

-

Switch ignition off.

-

Pull off rubber seal of plenum chamber cover in direction of - arrow -

-

Remove plenum chamber cover - 1 - toward front.