audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Leak Detection Pump (LDP) -V144-, Checking|Page 5276 > < Leak Detection Pump (LDP) -V144-, Checking|Page 5274
Page 5
background image

-

Connect test box V.A.G 1598/31 to wiring harness connectors, with Engine Control Module (ECM) not connected. Connect Ground (GND) clip at
test box to Ground (GND) (not visible in illustration).  See: Computers and Control Systems/Testing and Inspection/Reading and Clearing
Diagnostic Trouble Codes/Scan Tool Connecting/Test Box, Connecting For Wiring and Component Test

CAUTION:  To avoid damaging electronic components, switch to the corresponding measuring range and observe all test conditions before
connecting the test leads.

-

Check the following wire connection for open circuit and short circuit to Ground (GND) and B+:

Harness connector Terminal

Test box V.A.G 1598/31Socket

- 2 -

25

-

Repair wiring open circuit or short circuit according to wiring diagram.

If no malfunction is found, but leak diagnosis pump is not functional during output diagnostic test mode:

-

Replace Leak Detection Pump (LDP) V144

-

Observe procedures for after re-connecting engine control module (ECM).

Checking input wiring

-

Switch off ignition.

-

Connect test box V.A.G 1598/31 to wiring harness connectors, with Engine Control Module (ECM) not connected. Connect Ground (GND) clip at
test box to Ground (GND) (not visible in illustration).  See: Computers and Control Systems/Testing and Inspection/Reading and Clearing
Diagnostic Trouble Codes/Scan Tool Connecting/Test Box, Connecting For Wiring and Component Test

CAUTION:  To avoid damaging electronic components, switch to the corresponding measuring range and observe all test conditions before

Leak Detection Pump (LDP) -V144-, Checking|Page 5276 > < Leak Detection Pump (LDP) -V144-, Checking|Page 5274