audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Fuel Delivery Unit and Fuel Level Sensor, Assembly Overview - Up to 10.04|Page 5519 > < Fuel Delivery Unit and Fuel Level Sensor, Assembly Overview - Up to 10.04|Page 5517
Page 2
background image

14. Ground connection

-

For discharging electrostatic charge

-

Installed position / check requirements

-

After installing, check electrical connection of metal ring at fuel filler tube to a bare area of chassis using Ohm meter - Specified value: approx.
0 Ohm.

15. Ventilation line
16. Ventilation line

-

From gravity valve to EVAP canister

-

To remove, press release ring on EVAP canister

17. Ventilation line

-

From EVAP canister to Evaporative Emission (EVAP) Canister Purge Regulator Valve N80

-

To remove, press release ring on EVAP canister

-

Clipped in on fuel tank

18. Fuel tank
19. Spreader clip
20. 23 Nm
21. Securing strap
22. Heat shield

-

For fuel tank

23. 2 Nm
24. 23 Nm

Installation position of Ground (GND) connection

-

Route Ground (GND) connection as shown in illustration.

-

First hook Ground (GND) connection contact - 1 - into securing hole on fuel tank - 5. and then press in spacer bushing - 2-.

-

Make sure connector of Ground (GND) connection - 4. fits securely at metal ring - 3 - of fuel filler tube.

CAUTION:  After installing, check electrical connection of metal ring at fuel filler tube to a blank portion of chassis using Ohm meter:

-

Specification: approx. 0 Ohm.

Fuel Delivery Unit and Fuel Level Sensor, Assembly Overview - Up to 10.04|Page 5519 > < Fuel Delivery Unit and Fuel Level Sensor, Assembly Overview - Up to 10.04|Page 5517