audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Camshaft Position (CMP) Sensor, Checking|Page 4066 > < Camshaft Position (CMP) Sensor, Checking|Page 4064
Page 2
background image

-

Disconnect electrical harness connector -3- from Evaporative Emission (EVAP) Canister Purge Regulator Valve -N80- (item -2-).

-

Remove solenoid valve from bracket.

-

Disconnect electrical harness connector -4- at Mass Air Flow (MAF) sensor -G70-.

-

Rotate hose -1- to Secondary Air Injection (AIR) pump toward left and disconnect.

-

Disconnect air guide hose -5- at Mass Air Flow (MAF) sensor -G70-.

-

Remove bolt (arrow).

-

Remove air filter housing with Mass Air Flow (MAF) sensor -G70-.

-

Disconnect electrical harness connector (arrow) for Camshaft Position (CMP) Sensor -G40- at right cylinder head.

NOTE:  The illustration depicts the engine removed from behind.

-

Clamp off coolant hose -1- e.g. using hose clamp 3094 and disconnect from coolant expansion tank.

-

Remove coolant reservoir -2- (arrows).

-

Disconnect electrical wire from Engine Coolant Level (ECL) Warning Switch -F66- and set aside coolant reservoir with coolant hose -3-
connected.

-

If necessary, seal the connection using an appropriate plug.

Camshaft Position (CMP) Sensor, Checking|Page 4066 > < Camshaft Position (CMP) Sensor, Checking|Page 4064