S4 V8-4.2L (BHF) (2004)
-
Disconnect electrical harness connector - 1 - at right locking flange.
NOTE: Ignore - Pos. 2
-
Connect hand multimeter V.A.G 1526 B between terminal - 2 - and - 3 - for resistance measurement.
NOTE:
-
If measured value is 0 ohm. there is a short circuit. If measured value is Infinite Ohms there is and open circuit in the wiring.
-
To check resistance values "tank full" or "tank empty", the fuel level sensor G must be removed and the floater of the sensor must be pivoted
to the upper or lower end position.
-
With fuel level sensor G removed, the following values are obtained because of the greater deflection of the floater arm.