Immerse end of hydrometer in a cell and extract sufficient electrolyte so that float swims free in the electrolyte.
-

The greater the specific gravity of the electrolyte drawn in, the higher the float will ride.

-

The specific gravity in kg/cu.dm (specific gravity of electrolyte) can be read off the scale - arrow - on the hydrometer.

-

Take reading on hydrometer and compare to values given in table:

climatic zones must be at least 1.24 kg/cu.dm. If specific gravity is too low in all battery cells:

-

Charge battery and then repeat electrolyte specific gravity test.

Example 1:

Example 2:

If specifications are not obtained:

-

Replace battery.

NOTE:  The measured values for the electrolyte specific gravity of the individual battery cells must NOT deviate by more than 0.03 kg/cu.dm,
otherwise battery has to be replaced.

-

Reinstall battery sealing plugs.

CAUTION:

-

Battery openings must be fitted with the correct plugs to ensure that battery cover (different types.) is properly secured. Always use correct sealing
plugs (same as original equipment) in the event of loss or damage.

-

The plugs must be equipped with an O-ring seal.

Battery Installation, Checking|Page 7238 > < Battery Installation, Checking|Page 7236