S4 V8-4.2L (BHF) (2004)
-
Relieve ribbed belt tension by loosening tensioner bolt - arrow -
-
Remove ribbed belt from generator pulley.
-
Remove bolts - arrows - and remove tensioner.
-
Remove mounting bolts - arrows -.
-
Remove generator from bracket and pull forwards.
NOTE: If generator is difficult to remove from mounting, reinstall mounting bolts loosely and carefully strike bolt heads with hammer in order to
loosen mounting threaded bushings.
-
Release hose clamp - 3 - and remove coolant hose from generator.
-
Disconnect electrical connection -1-.