The upper point - arrow a - on the side with the cut-out - arrow c - at bottom is the longer side (max. marking). 

-

This side is used to check whether the window frame is located too far outward in relation to the chassis.

-

Position template at dimension - a - = 200 mm and with cut-out - arrow - facing door window

-

Make sure that points - 1 - and - 3 - make contact.

-

At point - 2 - of template, there must be a gap. 

-

In this position (max), doors are adjusted to farthest outward point within tolerance range.

-

If there is no gap at point - 2 -, or there is a gap at point - 1 -, the window frame is set too far outward and must be adjusted.

-

The upper point - arrow b - opposite the side with cut-out - arrow c - at bottom is the shorter side (min. marking). 