Connecting Rod: Testing and Inspection
Connecting Rod, Measuring Radial Clearance

Connecting Rod, Measuring Radial Clearance

Special tools, testers and auxiliary items required

‹› Plastigage

Test Sequence

-

Remove connecting rod bearing caps.

-

Clean bearing caps and journals

-

Place Plastigage over entire width of bearing journal or into bearing shells.

-

Install connecting rod bearing cap and tighten to 30 Nm. Do not turn crankshaft.

-

Remove connecting rod bearing caps again.

-

Compare width of Plastigage with measuring scale:

‹› Radial clearance new: 0.028 to 0.077 mm.

‹› Radial clearance wear limit: 0.12 mm.

-

Replace bolts for connecting rod bearings.