S4 Quattro Sedan V8-4.2L (BHF) (2005)
NOTE: When removing, be sure not to bend floater arm of fuel level sensor 2 G169.
-
Unclip suction jet pump from locking flange with Fuel Level Sensor 2 G169.
-
Remove locking flange with fuel level sensor 2 G169.
Installing
Installation is in reverse order of removal. Note the following:
NOTE:
-
Replace seal.
-
When installing, be sure not to bend floater arm of fuel level sensor 2 G169.
-
Clip suction jet pump to locking flange so that it is audibly engaged.
-
Carefully insert Fuel Level Sensor 2 G169 into fuel tank opening.
-
Install new locking flange seal dry.
-
Press locking flange down against spring pressure and bring it into installation position.
-
Tab - 2 - on locking flange must lie between tabs - 1 - and - 3 - on fuel tank.
NOTE: Arrow - points in direction of travel.
-
Tighten locking ring.
-
Connect battery. Observe safety precautions after connecting battery.
Torque specifications
Component
Nm
Lock ring for locking flange of
145
fuel level sensor 2 G169