audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Condenser HVAC > < Overview|Page 8258
Page 4
background image

-

Tighten drive plate - C - with 35 Nm by rotating it with a conventional band wrench (with webbed band) in the direction of arrow - F -,
counterhold compressor shaft - B - using a retainer (e.g. using a socket wrench (T10001/10) from the socket wrench set) on compressor shaft - B -.

-

Install circlip - A -.

-

Clean drive plate of belt pulley - A - and glue plastic disc - B - centered onto drive plate (only on compressors without rubber ring on circlip).