Control Module HVAC: Component Tests and General Diagnostics
A/C Compressor Regulator Valve, Checking Activation Signal

A/C Compressor Regulator Valve, Checking Activation Signal

-

Switch off ignition.

-

Connect the Climatronic control module (J255) A/C control head to the vehicle wiring harness.

-

Disconnect the connector from the A/C system compressor (to the A/C compressor regulator valve (N280)).

-

Recreate the connection between connector - A - and connector - B - on the compressor (to the A/C compressor regulator valve (N280)) using an
adapter cable from the connector test kit (V.A.G 1594C).

‹› An adapter cable can also be used for this test. To do this, e.g. use one connector each - A - and - B - (part number 1J0 973 702 and 1J0 973 802

and relevant terminal contacts), two standard sockets for banana connectors - C - and two wires with 0.5 mm 2 diameter.

-

Connect DSO measuring leads 1 & 2 (VAS 5051/8 ) to the adapter leads.

-

Measuring cable (signal wire) to terminal - 2 -. 

-

Measuring cable (shielded, ground) to terminal - 1 -. 

-

In Vehicle Diagnosis, Testing and Information System (VAS 5051A), select operating mode Test Instruments: " DSO" (digital storage
oscilloscope)

-

Setting 5V/div = 0.5 ms/div (5 volts DC voltage and 0.5 milliseconds per unit)

-

Start the engine.

Test Step 1|Page 8297 > < Test Step 1|Page 8295