Tighten screw - A - with 10 Nm (screws with an M6 thread) and to 25 Nm (screws with an M8 thread).

‹› First tighten screws - B - and then secure clamp -  C - with screw - A -.

‹› Do not use the O-rings from the shipping caps that are installed on the connections of replacement compressor when installing lines.

‹› Following attachment of refrigerant lines - A -, check the routing of the lines. They must be inserted in the provided holders -  B - and may not

come into contact with other components.