Receiver Dryer: Service and Repair
Receiver Or Accumulator and Restrictor, Replacing After Cleaning Refrigerant Circuit

Receiver Or Accumulator And Restrictor, Replacing After Cleaning Refrigerant Circuit

NOTE:  Cleaning refrigerant circuit means flushing it with refrigerant R134a or blowing through with compressed air and nitrogen).

For example, on account of ingress of moisture (refrigerant circuit open for lengthy period) or contamination

-

Discharge refrigerant circuit.

-

Remove compressor.

-

Rectify cause of trouble.

-

Clean refrigerant circuit (flush with refrigerant R134a or blow through using compressed air and nitrogen).

-

Examine expansion valve for dirt or corrosion and replace if necessary.

-

Remove oil drain plug from compressor.

NOTE:  The oil drain plug of "Denso/Nippondenso" compressors is equipped with an oil seal instead of an O-ring and this is always to be
replaced.

-

To accelerate drainage of refrigerant oil, rotate compressor by way of clutch plate of A/C clutch for example.

-

Pour old refrigerant oil out of compressor.

NOTE:  Disposal of old refrigerant.

-

Then fill compressor with quantity of fresh refrigerant oil corresponding to quantity of refrigerant oil in replacement compressor (or the specified
refrigerant oil quantity in vehicles with two evaporators if necessary).

NOTE:
-

Use different refrigerant oils and quantities for the various compressors.

-

To ensure compressor lubrication on start-up, at least 80 cu.cm of refrigerant oil must be poured into the compressor. The remainder can be
added for example to the new reservoir or receiver.

-

If dirt has penetrated into the compressor with the refrigerant circuit open (e.g. after an accident), compressor is to be replaced.

-

In vehicles with two evaporators, the refrigerant oil quantity in refrigerant circuit may be greater than the quantity already filled in the
replacement compressor, if necessary add the remaining refrigerant oil quantity to the refrigerant circuit.

-

Replace receiver or reservoir and restrictor.

-

Assemble, evacuate and charge refrigerant circuit.