audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Refrigerant Circuit|Page 8441 > < Refrigerant Circuit
Page 2
background image

2 - Compressor

‹› Remove the compressor from the bracket and reinstall it. Refer to => [ Compressor, Removing from Bracket ] See: Compressor

HVAC/Service and Repair/Compressor, Removing From Bracket and 1)

‹› When installing refrigerant lines/hoses and pertaining bracket, make sure there is a sufficient gap between belt, bracket and belt pulley

‹› The type of compressor differs depending on the engine (installed on the right or left of the engine).

‹› Depending on the country version, various compressor types are installed (e.g. "Denso" type designation "6 SEU" for Europe and "7 SEU" for

countries with a hot climate).

3 - Belt Pulley/Drive Unit - Compressor For Engine 

‹› Remove and install the ribbed belt. Refer to 1) and => Engine Mechanical See: Engine, Cooling and Exhaust/Engine

‹› Ribbed belt allocation.

‹› Check and replace the compressor drive unit. Refer to => [ Compressor Drive Unit ] See: Compressor HVAC/Description and

Operation/Compressor Drive Unit

‹› A rubber element is installed between the belt pulley/drive unit and the drive shaft of the compressor to protect the belt/gear drive in the event that

the compressor is seized or does not move freely.

‹› If compressor is not operating smoothly, rubber element interrupts power transmission to compressor.

‹› A rubber element is installed between the engine and the compressor to protect the gear drive if the compressor is blocked or not operating

smoothly. 

‹› Rubber element reduces vibration which may occur during compressor operation (damper function in the event of torque fluctuations).

4 - Oil Drain Plug

5 - High Pressure Relief Valve

6 - Connection With Valve

7 - High Pressure Sensor (G65 ) 1)

‹› Removing and installing, refer to => [ High Pressure Sensor ] See: Refrigerant Pressure Sensor / Switch/High Pressure Sensor / Switch/Service

and Repair

‹› Checking signal, refer to => [ Test Step 5 ] See: Testing and Inspection/Component Tests and General Diagnostics/Climatronic Control

Module A/C Control Head Electrical Test

8 - Condenser

9 - Cap

‹› With seal

‹› Always screw on

10 - Service Connection

‹› High pressure side

‹› Used for measuring, discharging and recharging by A/C system service point workshops

11 - Bolts In Refrigerant Line

12 - Restrictor

‹› Installed in the threaded connection - item 11

Refrigerant Circuit|Page 8441 > < Refrigerant Circuit