Control Module HVAC: Component Tests and General Diagnostics
High Pressure Sensor, Checking Pressure Signal

High Pressure Sensor, Checking Pressure Signal

This image is displayed on the oscilloscope screen when the following basic conditions are met.

-

Ignition on (positive and ground present at the high pressure sensor (G65)) 

-

Oscilloscope settings: 5V / Div. = (5V per unit DC voltage) 5 ms / Div. (5 milliseconds per unit)

-

Measuring lead (signal wire) connected to jack "7" of the test box (V.A.G 1598A) (with adapter cable (V.A.G 1598/12)).

-

Measuring lead (shielding) connected to jack "14" (ground) of the test box (V.A.G 1598A) (with adapter cable (V.A.G 1598/12)).

‹› The display shows a signal that is transferred when the pressure in the refrigerant circuit is approximately 7 bar, it corresponds to an approximate

duty cycle of 25% (with compressor not engaged, an ambient temperature of 30 °C and properly filled refrigerant circuit).

‹› The impulse width - A - depends on the pressure in the refrigerant circuit (if pressure increases, area - A - gets wider).

‹› The signal distance - B - is always 20 milliseconds (corresponds to frequency of 50 Hertz).

‹› The duty cycle is determined by the ratio of impulse width -  A - and signal distance - B -.