audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Solar Cell, HVAC|Testing and Inspection|Page 8571 > < Solar Sensor, HVAC|Service and Repair
Page 1
background image

Solar Cell: Testing and Inspection

Solar Roof Electrical Test

=> [ Solar Roof, Checking Function ] 

‹› Solar ventilation function only works when the sunroof is either closed or in the raised position. The solar sunroof converts the solar energy into

electrical energy which then passes into the vehicle electrical system via terminals - A - (on the front of the sunroof) and terminals -  B - (on the
frame of the sunroof).

‹› Solar operation is not possible with ignition switched on and with parking heater/parking ventilation running (Fresh Air Blower Control Module

(J126) breaks the connection between solar roof and Fresh Air Blower (V2)).  

‹› On vehicles without sunroof, all A/C system control motors remain standing in their current positions at the moment when the ignition is switched

off. However, in order to ventilate the vehicle interior when the system is in solar ventilation mode, the fresh air/recirculated air door must be in
the " fresh air" position. Therefore on vehicles with solar roof, the A/C control head Climatronic Control Module (J255) sends via the coding the
indication that the vehicle is equipped with a sunroof with Solar Cells (C20). A/C control head Climatronic Control Module (J255) then moves the
doors on the heating and A/C unit into the "fresh air" position after ignition is switched off.

‹› The energy supplied by the Solar Cells (C20) is conveyed directly to the Fresh Air Blower (V2) via Fresh Air Blower Control Module (J126). The

fresh air blower (V2) converts the generated electrical energy into blower output.

‹› With the ignition switched off (no signal detected from the Climatronic control module (J255) A/C control head), the fresh air blower control

module (J126) checks the voltage at the input of the solar cells in regular intervals and converts the voltage generated by the solar cells in such a
way that the fresh air blower (V2) runs at the highest possible speed when there is sufficient solar energy.

‹› The electrical energy transferred from the Solar Cells (C20) at a solar radiation level of 500 W / m2 is approximately 12 W:

500 W / m2(solar irradiation) x 0.21 m2 (solar cell surface area on sunroof) x 0.13 (efficiency of Solar Cells (C20)) x 0.9 (efficiency of Fresh Air
Blower Control Module (J126)).

‹› Terminals - A - and - B - (on the sunroof and sunroof frame) are used to transfer the electrical energy generated, and must always be clean and free

of conventional lubricating grease.

‹› If necessary, terminals - A - and - B - can be lightly coated with contact grease (electrically conductive protective lubricant, available from

suppliers of electronic equipment).

Solar Roof, Checking Function

-

Place vehicle in direct sunlight.

‹› If weather conditions are unfavorable, the solar sunroof can be illuminated using two commercially available 1000 W halogen lamps. A distance of

at least 500 mm from the solar roof must be maintained. Make sure that all sunroof Solar Cells (C20) are illuminated completely and evenly so that
the Solar Cells (C20) can supply sufficient electrical energy to drive the Fresh Air Blower (V2),

-

Open the "center" instrument panel vents and close the remaining vents.

Solar Cell, HVAC|Testing and Inspection|Page 8571 > < Solar Sensor, HVAC|Service and Repair