audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Oxygen Sensors Before Catalytic Converter, Checking Heater|Page 3547 > < Oxygen Sensor|Locations
Page 1
background image

Oxygen Sensor: Testing and Inspection
Oxygen Sensors Before Catalytic Converter, Checking Heater

Oxygen Sensors before Catalytic Converter, Checking Heater

The following procedure is used to diagnose Oxygen Sensor (O2S) Heater (Z19) and Oxygen Sensor (O2S) 2 Heater (Z28).

‹› When servicing electrical harness connector terminals for the Heated Oxygen Sensor (HO2S) (G39), use only gold-plated terminals.

Special tools, testers and auxiliary items required

‹› Multimeter.

‹› Wiring diagram.

Test requirements

‹›  The Oxygen Sensor (O2S) Heater (Z19) and Oxygen Sensor (O2S) 2 Heater (Z28) Engine Electronics Fuse (S282) OK.

‹› The Fuel Pump (FP) Relay (J17) OK.

‹› Battery voltage at least 12.5 volts.

‹› All electrical consumers such as, lights and rear window defroster, switched off.

‹› Vehicles with automatic transmission, shift selector lever into position " P" or "N".

‹› A/C switched off.

‹› Ground (GND) connections between engine/transmission/chassis OK.

‹› Ignition switched off.

Procedure for accessing Oxygen Sensor (O2S) 2 Heater (Z28) electrical harness.

-

Remove the left side engine compartment cover - 1 -. 

-

Remove the coolant expansion tank screw - arrow -. 

-

Disconnect the electrical connector from the Engine Coolant Level (ECL) Warning Switch (F66) and set aside coolant reservoir with coolant hoses
1 -and - 2 - connected. 

Oxygen Sensors Before Catalytic Converter, Checking Heater|Page 3547 > < Oxygen Sensor|Locations