audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Batteries Central Gas Venting, Checking|Page 5986 > < Batteries Central Gas Venting, Checking|Page 5984
Page 1
background image

Battery: Component Tests and General Diagnostics
Electrolyte Specific Gravity, Batteries With Sealing Plugs, Checking

Electrolyte Specific Gravity, Batteries with Sealing Plugs, Checking

CAUTION!
‹› Prior to handling or servicing batteries, read, understand and observe the Warning and Safety Measures for lead-acid batteries => [

Smoking, naked flames, fires and sparks: ] See: Service Precautions. 

‹› Always wear suitable protective clothing => [ Eye protection and protective clothing: ] See: Service Precautions. 

‹› When disposing of batteries, always pay attention to the appropriate regulations for batteries and sulfuric acid. 

‹› Proper battery sealing plugs must be used to ensure differing battery cover systems are sealed correctly. Use genuine sealing plugs of

same construction if lost or damaged.

‹› The plugs must be installed with an O-ring seal. 

Special tools, testers and auxiliary items required

‹› Hydrometer (commercially available)

‹› The electrolyte specific gravity test in conjunction with the battery test provides specific information on battery condition.

‹› The temperature of the battery electrolyte must be at least 10 °C. 

‹› Electrolyte specific gravity can be checked immediately after charging battery.

Test sequence

-

Remove all battery plugs (battery cell sealing plugs).

-

Immerse end of hydrometer in a cell and extract sufficient electrolyte so that float swims free in the electrolyte.

Batteries Central Gas Venting, Checking|Page 5986 > < Batteries Central Gas Venting, Checking|Page 5984